Housing with the same specifications as the EXHD |
|
Cylindrical body enclosed by two 9mm-thick circular flanges |
|
IP66 |
|
Single multi-core cable ready wired up, included with the unit, comes out of the base of the P&T through a cable gland |
|
Horizontal range 360°, for fixed speed: 6°/s, vertical range -90° / +90° for fixed speed: 2.4°/s |
|
Equipped as standard with housing heater and preset; as options with housing sunshield, autopan and replacement film |
|
Version available with reinforced (triple) housing 24Vac, (double) P&T heater 24Vac and special painting for low temperature applications (mod. EXPTD035R) |
|
Certificates:
- ECEx Ex d IIC T6 Ex tD A21 IP66 T85°C,
- ATEX Ex 2 GD Ex d IIC T6 tD A21 IP66 T85°C,
- GOST-R 1ExdIICT6 и DIP A21 TA T6 |
| |
|
General |
|
Non-corrosive die-cast aluminium (anticorodal) |
|
Bicomponent polyurethane enamel with orange peel effect, RAL7032 |
|
Special painting for low temperature, blue colour (EXPTC033R, EXPTD035R, EXPTWB00R). Resistant to stress cracking, adverse weather conditions, detergents, salt-spray and typical airborne pollutants |
|
Supplied with instruction manual and conformity declaration |
| |
|
Mechanical |
|
0-360° horizontal movement |
|
Horizontal speed: 6°/s |
|
Horizontal Torque: 2.5kgm |
|
+/-90° vertical movement |
|
Vertical speed: 2.4°/s |
|
Vertical torque: 6kgm |
|
Horizontal limit switch adjustable only for the Autopan function |
|
1 cable gland 3/4” GAS for armoured cable at the base of the P&T |
|
One multiconductors armoured cable normally supplied 7.5m (24ft) length: |
|
25 poles 0.5mm, 4 poles 1mm, 2 RG174 of 75W |
|
External dimensions |
|
EXPTC 427.5x571.4x560mm (16.8x322.5x22in) |
| |
EXPTD 573.5x581x580mm (22.6x22.9x22.8in) |
 |
Internal dimensions |
| |
EXPTC Ø 180x380mm (7x14.9in) |
| |
EXPTD Ø 180x460mm (7x18.1in) |
 |
Internal usable area |
| |
EXPTC 100x100x280mm (3.9x3.9x11in) |
| |
EXPTD 100x100x360mm (3.9x3.9x141in) |
 |
ATEX ( TUV Nord Certification), directive 94/9/CE |
| |
Group: II (surface device, no mining) |
| |
Category: 2 (elevated protection degree, the devices of this category can be installed in zone 1 and 21 and in zone 2 and 22) |
| |
Atmosphere type: GD (gases and dusts) |
| |
EEx d: explosion-proof housing for potentially explosive environments |
| |
IIC: gases group |
| |
T6-T85°C: temperature classification for gases and dusts respectively |
| |
IP65: enclosure weatherproof standard |
 |
EXPTC000 - EXPTC010 - EXPTC033R - EXPTD001 - EXPTD011 - EXPTD035R |
| |
Ex d IIC T6 Ex tD A21 IP65 T85°C IECEx |
| |
Ex II 2 GD EExd IIC T6 T85°C IP65 ATEX |
| |
Ex 0044: notify number from competent body |
| |
UL certification pending |
| |
GHOST-R certification pending |
 |
Window |
| |
EXPTC Ø 114mm (4.5in) |
| |
EXPTD 70x56mm (2.7x2.2in) |
| |
Glass protection device |
| |
Glass protection device: Ø 250x140mm (9.8x5.5in) |
| |
Mylar film 80mm (3.1in) wide and 18m (59ft) length, 350 shifting steps, marks printed on the last 50cm (19in) |
 |
Wall Bracket |
| |
Load rating: 100kg (220lb) |
| |
Length: 676mm (26.6in) |
| |
|
Compliance To |
 |
IECEx (TUV Nord Certification), protocols IEC 60079-0:2000, IEC 60079- 1:2001, IEC 61241-1:2004 |
 |
Ex d: explosion-proof housing for potentially explosive environments |
 |
IIC: gases group T6: device class temperature |
 |
Ex tD A21: dust ignition protection, zones type 21-22 |
 |
IP65: enclosure weatherproof standard |
 |
T 85°C: max superficial temperature |